Henny Penny OG-30X Fryer User Manual


 
The filter switch is a two way rocker switch with the switch
in the “ON” position, the filter motor energizes to pump up
the shortening from the drain pan.
1. Remove power supplied to the unit, or on electric models,
to the far right cookpot that powers the filter switch.
Disconnect power supplied to the unit by unplugging
the power cord, or turning off the wall circuit breaker
or fuse. Be aware that the other control will have power
on electric models, or electrical shock could result.
2. Remove the middle control panel per section 6-3.
3. Remove and label wires from the switch and check across
top and bottom terminals for continuity. With the switch
in the “ON” position, the circuit should be closed. If the
switch is defective, replace it by following the next steps.
4. Push in tabs on the ends of the switch and pull switch from
the front of the control panel.
5. Replace new switch, replace wires, and install panel.
6. Re-apply power to unit.