6-1.
ENTS
This section provides procedures for checking and replacement
of the various parts used within the unit. Before replacing any
parts, refer to Section 5, Troubleshooting. It will aid you in
determining the cause of a particular malfunction.
You may want to use two test instruments to check the elec-
tric components.
0 A continuity light
0 An ohmmeter
When the manual refers to a circuit being closed, the continuity
light will be illuminated or the ohmmeter should read (0) unless
otherwise noted.
When the manual refers to the circuit being open, the continui-
ty light will not illuminate, or the ohmmeter will read (1).
A continuity light cannot be used to check coils or motors.
To replace parts located inside the fryer, the control panel must
be removed, or hinged down.
1. Place the power switch in the OFF position and remove
power supplied to the unit, or on electric models, to the
cookpot to be worked on.
Disconnect power supplied to the unit by unplugging the power
cord, or turning off the wall circuit breaker, or fuse. Be aware
that the other controls will HAVE power on electric models,
or electrical shock could result.