Taylor C716 Refrigerator User Manual


 
22
Models C708 & C716Important: To the Operator
080222
To comply with health codes, heat treatment system
freezers must complete a heat treatment cycle
daily, and must be dis assembled and brush cleaned
a minimum of every 14 days. Brush cleaning is the
normal disassembly and c leaning procedure found in
the Operator Manual. Failure to follow these
guidelines will c ause the control to lock the freezer
out of the AUTO mode.
If the Heat Treatment Cycle fails, the screen will
display a failure message and return the freezer to
the STANDBY mode.
Always comply with local guidelines for the
maximum number of days allowed between brush
clean cycles.
Freezer Locks
There are two t ypes of freezer lock conditions that
can occur: Hard Lock or Soft Lock. A Hard Lock
requires the machine be disassembled and brush
cleaned. A Soft Lock can be c orrected by either
disassembling and brush cleaning the m achine, or
by starting another heat treatment cycle.
Hardlock
There are two causes of a hard lock failure. The
freezer will hardlock if either the Brush Clean Timer
has elapsed or if a Thermistor Failure (Freezing
Cylinder or Hopper) occurred during a Heat cycle.
1. The following screen will be displayed if a B rush
Clean Cycle Time has occurred.
BRUSH CLEAN TIMEOUT
FREEZER LOCKED
CLEANING REQ'D
> WASH TO BRUSH CLEAN
Touching the SEL symbol will dis play the f ollowing
screen.
FREEZER LOCKED
2. The following screen will display if there has
been a thermistor failure (freezing cylinder or
hopper) during the heat treatment process.
SYSTEM FAULT
FREEZER LOCKED
SERVICE REQ'D
> WASH TO BRUSH CLEAN
Touching the SEL symbol will indic ate which
thermistor caused the H ard Lock.
HOPPER THERM BAD
FREEZER LOCKED
If the machine has hard locked and an attempt is
made to enter AUTO, the machine will enter the
STANDBY mode and display the following m essage.
FREEZER LOCKED
To restore the message that identified the reason for
the hard lock, turn the power s witch OFF for five
seconds and then return the power s witch to the ON
position. The original message with the reason for
the Hard Lock will be displayed.
The FREEZER LOCKED message will remain on
the display until the brush c lean requirements are
fulfilled. The freezer must be disassembled in order
to activate the five minute timer on the dis play
screen. Once the timer counts down to zero, the
lockout is cleared.