Taylor C716 Refrigerator User Manual


 
37
Models C708 & C716 Operating Procedures
To INCREASE the flow rate, turn the adjustment
screw CLOCKWISE. To DECREASE the flow rate,
turn the adjustment screw COUNTER-
CLOCKWISE.
Step 9
Snap the design c aps ov er the bottom of the door
spouts.
Step 10
Slide the two rear dr ip trays into the holes in the
back panel. Slide the two drip pans int o t he holes in
the side panels. (See Figure 28.)
Figure 2 8
Step 11
Install the front drip tray and splash s hield under the
door spouts. (See Figure 29.)
Figure 2 9
Mix Pump Assembly
Step 1
Inspect the rubber pump parts. O-rings and gasket
must be in 100% good condition for the pump and
entire machine to oper ate p roperly. The o-rings and
gasket cannot properly serve their intended function
if nicks, cuts, or holes in the material are present.
Replace any defective parts immediately and
discard the old.
Step 2
Assemble the p iston. Slide the red o-ring into the
groove of the piston. DO NOT lubricate the o-ring.
(See Figure 30.)
Figure 3 0
Step 3
Apply a thin lay er of lubricant to the inside o f the
pump cylinder at the retaining pin hole end.
(See Figure 31.)
Figure 3 1