Taylor C716 Refrigerator User Manual


 
29
Models C708 & C716 Important: To the Operator
051025
POWERFAILINH/C-A power failure occurred
during the heat treatment cycle.
MIX LOW FAILURE - The mix level in the hopper is
too low for a successf ul heat cycle.
BEATER OVLD H/C - The overload tripped for the
beater motor.
BRL THERM FAIL - The thermistor sensor for the
freezing cylinder failed.
HOPPER THERM FAIL - The thermistor sensor for
the hopper failed.
HPCO H/C - The high pressure switch opened
during the heat treatment cycle.
Faults Occurring While in AUTO Mode
(L/R) HPR>41F (5C) AFTER 4 HR - The mix
temperature in t he hopper was above 41°F (5°C)
more than four hours.
(L/R) BRL>41F (5C) AFTER 4 HR - The mix
temperature in t he f reezing cylinder (barrel) was
above 41°F (5°C) more than four hours.
(L/R) HPR>41F (5C) AFTER PF - The mix
temperature in t he hopper was above 41°F (5°C)
more than four hours following a power failure.
(L/R) BRL>41F (5C) AFTER PF - The mix
temperature in t he f reezing cylinder (barrel) was
above 41°F (5°C) more than four hours following a
power failure.
(L/R) HPR>45F (7C) AFTER 1 HR - The mix
temperature in t he lef t or r ight hopper was above
45°F (7°C) more than one hour.
(L/R) BRL>45F (7C) AFTER 1 HR - The mix
temperature in t he lef t or right freezing cylinder
(barrel) was above 45°F (7°C) more than one hour.
(L/R) HPR>59F (15C) - The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C) - The mix temperature in the
freezing cylinder (barrel) exceeded 59°F (15°C).
Heat Cycle Summary
The HEAT CYCLE SUMMARY screen displays the
hours since t h e last heat cycle, the hours since the
product temperature was above 150_F (65.6_C),
and the number of heat cycles completed since the
last brush clean date.
HEAT CYCLE SUMMARY
HRS SINCE HC 0
HRS SINCE 150 0
HC SINCE BC 0
Heat Cycle Data
The HEAT CYCLE DATA screen contains a record
of up to 366 heat treatment cycles. The most recent
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the m onth and day of the heat cycle,
the start time and end time, and the fault description.
The bottom line dis plays the r ecord number and
indicates if a power failure occurred during the heat
cycle (POWER FAILURE IN HC).
HEAT TREAT CYCLE
01/01 02:00 05:14
NO FAULT FOUND
1
Touch the UP arrow symbol to advance forward
through the data pages . Touch the DOWN arrow
symbol to reverse the page direction.
Hopper and bar rel temperature records for each side
of the freezer are displayed in the second and t hird
screens. The second screen shows the left side (L)
side of the freezer.