46
Models C708 & C716Operating Procedures
100507
Step 3
When the flow of product stops, touch the WASH
and PUMP symbols
, cancelling the WASH
and PUMP modes. Close the draw valve. Properly
dispose of the mix. (See Figure 55.)
Figure 5 5
Step 4
Remove the locking clip, mix feed tube, pump c lip
and the a ssembled air/mix pump.
Repeat these steps for the other side of the
Model C716.
Rinsing
Step 1
Pour two gallons (7.6 liters) of cool, clean water into
the mix hopper. With the white hopper brush, scrub
the mix hopper, mix level sensing probe and the
outside of the agitator drive shaft housing. Using the
double ended brush, brush clean the mix inlet hole.
(See Figure 56.)
Figure 5 6
Note: Do not brush c lean t he mix inlet hole while
the machine is in the WASH mode.
Step 2
With a mix pail beneat h the door spout,(s) open the
draw valve and t ouch the WASH symbol .
(See Figure 57.)
Figure 5 7
Step 3
Drain all the rinse water from the door spout. Close
the draw valve and touch the WASH symbol,
cancelling the WASH mode.
Step 4
Repeat this procedure using clean, warm water, until
the water being discharged is c lear.
Repeat these steps for the other side of the
Model C716.
Hopper Cleaning
Step 1
Prepare a n approved 100 PPM cleaning solution
(examples: 2-1/2 gal. [9.5 liters] of Kay-5R or 2
gal. [7.6 liters] of Stera-SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 2
Pour the solution into the hopper and allow it to flow
into the freezing cylinder.
Step 3
Using the white hopper brush, clean the mix hopper,
mix level sensing probes and the outside of the
agitator drive shaft housing. Using the double ended
brush, clean the mix inlet hole. (Note: Do not br ush
clean the mix inlet hole while the machine is in the
WASH mode.)