Teledyne 6712FR Refrigerator User Manual


 
6712FR Refrigerated Sampler
Section 4 Standard Programming
4-32
8
PROGRAM MODULE?
YES NO
Select YES to program the module.
9
MODE OF OPERATION:
FLOWMETER
LEVEL AND VELOCITY
The 750 can have two different modes of operation: Flowmeter or Level and
Velocity.
For this example, choose Flowmeter. Press
.
10
FLOW CALCULATION:
AREA * VELOCITY
LEVEL TO FLOW RATE
When you select Flowmeter, you will have two options for performing the
flow conversion: Area * Velocity or Level to Flow Rate.
For this example, choose Area * Velocity. Press .
11
LEVEL TO AREA:
CHANNEL SHAPE
DATA POINTS
For this example, choose Channel Shape. Press .
12
ROUND PIPE
U-CHANNEL
RECTANGULAR CHANNEL
TRAPEZOIDAL CHANNEL
For the channel shape, select Round Pipe. Press .
13
ROUND PIPE
DIAMETER = 2.00 ft
Enter the diameter of the round pipe. Press .
14
CURRENT LEVEL IS
__.__ ft
ADJUST LEVEL TO
__.__ ft
The current level will be displayed. Enter an adjustment if needed. If the
adjustment is different by more than 0.50 ft, you will be prompted “
ARE YOU
SURE
? YES NO” Choose NO to re-enter; select YES if correct. Press .
15
ZERO LEVEL OFFSET:
_.___ ft
Enter the amount of zero level offset. Press .
16
MAXIMUM DEPTH FOR
VELOCITY MEASUREMENT
2” 3” 4”
(This screen is applicable for standard-sized probes only.)
Select the maximum depth for the velocity measurement. Press
.
17
NUMBER OF BOTTLES:
12481224
Select the number of bottles in your bottle kit by pressing either arrow key
until the correct number blinks. Press
.
From this point forward, the screens will be the same as in Table 4-2.
Table 4-5 Programming Example With 750 Module Installed (Continued)