THE FILTERING SYSTEM
3. Remove Jetplates (page 55).
4. Remove Air Diverter Plate.
5. Remove the Catalytic Converter.
6. Clean the Catalytic Converter with TurboChef
Oven Cleaner (P/N 103180).
CAUTION: DO NOT use a substitute
cleaner.
7. Rinse thoroughly with distilled water.
CAUTION: Use distilled water only.
8. Let the Catalytic Converter air dry before
reinstalling.
9. If necessary, replace the Catalytic Converter
with P/N HHB-8108.
Filters (Figure 59)
The two Filters help prolong the life of the
Catalytic Converter by trapping excess grease.
They are attached to the Air Diverter Plate via the
Filter Clips. When deep cleaning the oven (see
page 59), the operator/technician should check to
see if the Filters need to be replaced.
To remove a Filter:
1. Ensure “Cool Down” process is completed. (“Cool
Down” message will disappear upon completion.)
2. Remove Oven Rack.
3. Remove Jetplates (page 55).
4. If more room to operate is necessary, remove the
Air D
iver
ter Plate.
5. Unfasten the Filter Clip from the center of the
Air Div
erter Plate.
6. Swing the clip open and remove the Filter.
7. If necessary, replace it with P/N HHB-8114.
8. Reconnect the clip and reinstall all components.