3M 965AMS Refrigerator User Manual


 
199
3M™ Dynatel™ Advanced Modular System 965AMS Specifications
Specifications
Electrical Specifications
Functions Range Resolution Accuracy
Voltage (DC) 0 to 99.9 V
100 to 300 V
0.1 V
1 V
1% ± 0.5 V
3%
Voltage (AC)
Meter resistance
100 k or 1 m
0 to 99.9 V
100 to 250 V
0.1 V
1 V
1% ± 0.5 V
3%
Current
Shunt resistance
0 to 59.9 mA
60 to 110 mA
430 Ω
0.1 mA
0.1 mA
1% ± 0.3 mA
2%
Resistance
With CO voltage
0 to 9999 Ω
0 to 9999 Ω
10 k to 99.9 kΩ
100 k to 999 kΩ
1 M to 9.9 MΩ
10 M to 99 MΩ
100 M to 990 MΩ
1 Ω
1 Ω
0.1 kΩ
1 kΩ
10 kΩ
0.1 MΩ
1 MΩ
1% ± 5 Ω
1% ± 50 Ω
1%
3%
3%
5%
10%
Opens (no noise) 0 to 3,000 ft
(0 to 1,000 m)
3,000 to 10,000 ft
(1 km to 3 km)
10,000 to 50,000 ft
(3 km to 15 km)
50,000 to 100,000 ft (15
km to 30 km)
1 ft (1 m)
1 ft (1 m)
10 ft (10 m)
100 ft (100 m)
1% ± 3 ft (1 m)
3%
5%
10%
RFL
Fault range
Resistance to
Fault (no noise)
0 to 20 MΩ
0 to 99.99 Ω
100 to 999.9 Ω
1 k to 3 kΩ
RTS 0.01 Ω
RTS 0.1 Ω
RTS 1.0 Ω
0.1% of RTS ± 0.01 Ω
1
0.2% of RTS ± 0.01 Ω
1
1.0% of RTS ± 0.01 Ω
1
Wet section test
Loop resistance Resistive
balance
0 to 7 kΩ
0 to 3.5 kΩ
5%
Loop resistance 0 to 99.9 Ω
100 to 999.9 Ω
1000 to 7000 Ω
0.01 Ω
0.1 Ω
1 Ω
0.1% ± 0.01 Ω
0.2% ± 0.01 Ω
1.0% ± 0.01 Ω
Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance
± 0.01 Ω
Note:
1
All resistance to fault measurement accuracies have an added factor of (2x10
-8
) R
f
ohms (R
f
=fault resistance in ohms)