3M 965AMS Refrigerator User Manual


 
32
Measurement Functions 3M™ Dynatel™ Advanced Modular System 965AMS
Ohms Measurements
The Ohms Measurement function measures the insulation
resistance between the Tip, Ring and Ground. This function
can also measure the resistance of the Tip and Ring loop or
individual wires.
Ohms Measurements>Hook-Up
RED
GRN
BLK
Ring (B)Ring (B)
Ground (Earth)
Ground (Earth)
Tip (A)
Tip (A)
Ohms Measurements>Operation
1. Press the blue
key to
start the ohms measurement
function.
2. This screen displays the
T-R resistance in the larger
active measurement box.