Measurement Functions 3M™ Dynatel™ Advanced Modular System 965AMS
RFL>Wet Pulp> Requirements
Note: All of the following conditions must be met or this
function does not apply:
1. One fault must be at least twice the ohms value of the other
fault. For example, a 5 kΩfault has twice the value of a
10 kΩfault.
2. The sum of both faults must be at least 100 times the loop
resistance of the pair. For example, if the loop resistance is
50 Ω, the sum of the faults must be 5 kΩor greater. You may
continue with the test, but the results may have a reduced
accuracy.
3. The 965AMS checks to see if the resistance of the loop
is less than 7 kΩ. If the resistance is greater than 7 kΩ,
the distance to strap may be too long or the strap is not
connected,
RFL>Wet Pulp>Operation
1. Press the blue
key to
enter the RFL function.
Use the up and down keys
to select Wet Pulp.
Press
Setup
to select the
gauge of the pair.