Mitsubishi Electronics SW1D5-EXP-O-E Frozen Dessert Maker User Manual


 
5 - 13 5 - 13
MELSOFT
5 BASIC OPERATIONS
5.4 Basic Operations for PLC Side Window
5.4.1 Displaying the PLC configuration information
If there is no network configuration information at an initial start or like, display the
connection stations and network configuration in the PLC side window in the following
procedure.
(1) Operation sequence
1) Choose the PLC side window and click the [Online] -
[Transfer setup] menu.
2) Choose the PLC series in the Select PLC series dialog
box.
3) On the Transfer setup screen, set the "PC side I/F",
"PLC side I/F" and others and click the OK
button.
(Refer to (2) for the Target setup screen.)
Making Target setup automatically starts a connection
station check which confirms the PLC types of the
connection stations and the presence/absence of
networks. (Refer to POINT in Section 5.1.1 for the
connection station check.)
4) Click the [View] - [Network configuration information
refresh] menu.
5) In the dialog box designed to confirm the updating of the
network configuration information, choose "Get all
stations" or "Connection station only".
• "Get all stations" ................... Updates the network
presence/ absence and
the PLC types, memory
names and stored data of
the connection stations
and all stations of each
network.
• "Connection station only" ..... Updates the network
presence/ absence and
the PLC types of the
connection stations.