7 - 1 7 - 1
MELSOFT
7 MANAGEMENT OF DATA IN THE PLC CPU
7 MANAGEMENT OF DATA IN THE PLC CPU
This chapter describes write/read to/from the PLC CPU displayed in the PLC side
window and data editing and deletion.
7.1 Write/Read to/from PLC CPU
GX Explorer can perform write/read to/from PLC using project or data cut/copy and
paste (drag and drop).
Write-enabled data vary with the memory type.
For write-enabled data, refer to the user's manual of the PLC CPU being used.
GX Explorer cannot perform online program correction to the PLC CPU.
Making online program correction to the PLC displays the remote STOP confirmation
dialog box.
Click the Yes button to execute write to PLC after remote STOP.
After completion of write to PLC, perform remote operation (refer to Section 7.4.2
(QCPU (Q mode), QnACPU only)) or move the RUN/STOP switch of the PLC CPU to
RUN.
Click No
when you are not executing remote STOP and write to PLC.
7