Amana RSS Range User Manual


 
OPERATION AND SERVICE PROCEDURES
Electronic Range Control (ERC) (Models w/ Two Piece Control)
39 RC231002 Rev. 3
When the ERC initiates the bake operations, a volt-
age reading of approximately 24 VDC should be
indicated. If no voltage is indicated, check for the
input supply voltage at pins J1-3 and J1-4 (Step 3).
5. To check the broil relay drive voltage, insert your DC
voltmeter leads into the J1 connector at pins J1-8 and
J1-5, and program the ERC for a broil operation.
When the ERC initiates the broil operation, a voltage
reading of approximately 24 VDC should be indi-
cated. If no voltage is indicated, check for the input
supply voltage at pins J1-3 and J1-4 (Step 3).
TO AVOID THE RISK OF ELECTRIC SHOCK, PERSONAL INJURY OR DEATH DISCONNECT POWER
BEFORE SERVICING, UNLESS TESTING REQUIRES IT.
Figure 40 - Electronic Range Control Rear View