CMS Products 674 Coffeemaker User Manual


 
HotCup Operators’ Guide Initial Setup
November, 2007 13 6740001
Initial Setup
I. LOCATION PREPARATION
After your machine is unpacked and placed near its permanent location, you need to make sure you
have the proper electrical and water service.
ELECTRICAL POWER REQUIREMENTS
This merchandiser needs electrical power as shown in the following table.
NOTE:
Each merchandiser should have its own electrical circuit.
CHECK THE POWER OUTLET
This merchandiser is supplied with a service cord for the country of use and is terminated in a
grounding type plug. The wall receptacle used for this merchandiser must be properly polarized,
grounded, and of the correct voltage. Operating the merchandiser from a source of low voltage will
VOID YOUR WARRANTY. Each merchandiser should have its own electrical circuit and that circuit
should be protected with a circuit breaker or fuse conforming to local regulations.
Voltage Check - Place the leads of a voltmeter across the LINE (LIVE) and NEUTRAL
terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt,
60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations.
Polarity Check - Place the leads of a voltmeter across the LINE (LIVE) and GROUND
terminals of the wall receptacle. The voltmeter should indicate 110-130 volts ac for 120 volt,
60 Hz locations, or 220-240 volts ac for 230 volt, 50 Hz locations.
Noise Potential Check - Place the leads of a voltmeter across the NEUTRAL and GROUND
terminals of the wall receptacle. The voltmeter should indicate 0 volts ac. A measurement
greater than 1.5-2.0 volts ac could result in problems for the merchandiser's electronic
circuitry caused by electrical noise.
Any deviation from these requirements could result in unreliable performance from your
merchandiser.
POWER REQUIREMENTS
Country Volts Frequency
(Hz)
Current
(Amps)
Canada 115 60 15
France 230 50 10
Germany 230 50 10
United
Kingdom
230 50 10
United States 115 60 15