31
Hardware Output mode will monitor the power supply current when any (and only) one of the ll valve,
detergent diverter, water softener, wash/drain motor, drying fan is being operated, so do not run combinations of
outputs.
If the current is too high or too low, a fault with a component is present, and the controller will beep with a long
low tone repeated every second.
Dierent combinations of outputs can be switched on or o together, but the controller will prevent higher
current drawing components such as the wash pump and the lid motors being turned on together.
Press START/PAUSE to advance to the next hardware output.
Press KEYLOCK to turn the currently displayed output on or o. If the green LED on integrated or blue LED on
designer above start/pause button is displayed, then that output has been switched on, and if it is not displayed
then that output is o.
Press POWER to exit at any time (all outputs will be switched o on exit).
The LCD display and touch switch panel LEDs are illuminated to correspond to a particular hardware device. The
following table details the display order of the test.
LCD Heav Norm Fast Deli Rinse Hardware Output
-------------------------------------------------------------------------------------------
bL O O O O On Backlight
Er O O O On O Element Relay (turns o after 5 seconds)
Ld O O O On On Lid Motors (will run up to 10 seconds)
dd O O On O O Detergent Diverter Valve
FU O O On O On Fill Water Valve
P1 O O On On O Motor Wash direction 2200-2800 rpm (will not run if the tub is open)
P2 O O On On On Motor Drain direction 4200 rpm (times out after 255 seconds.)
rd O On O O O Rinse Aid Dispenser (dispenses according to current user setting)
dF O On O O On Drying fan
LE O On O On O Rinse Aid and Salt Tank LEDs
C1 O On O On On Water Softener Diverter Valve
C2 O On On O O Water Softener Brine Pump
C3 O On On O On Water Softener Brine Valve
A1 O On On On O Rinse Aid Pump (operates as a valve for diagnostic purposes only)
o
C O On On On On Displays current water temperature.
o
E On O O O O Displays controller rail voltage
(C3 is used in the factory to empty the water softener before the product is packed.)
WARNING: Take care when running individual components not to overload them. It is advisable to place some
water in the tub before turning the element on.
Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED on
integrated badge) indicates the tub position. On = closed, o = open.
To skip to the next level, press POWER button: