Sub-Zero Sub-Zero Freezer User Manual


 
42
INSTALLATION OPTIONS
The illustrations show some typical installations
and their dimension considerations. The depth
dimension in the illustrations may vary depend-
ing on cabinet styles, treatment of countertops
or other design options.
IMPORTANT NOTE: The depth of each
Integrated model is 610 mm from the front of
the unit to its back. Your design may necessitate
moving the unit back or cabinets forward to
achieve a flush fit. This will require a minimum
rough opening depth of 635 mm. Refer to the
illustrations.
NOTE: In the Installation Options illustrations,
the first width dimension shown is for 686 mm
wide units and the second dimension is for 914
mm wide units.
DUAL INSTALLATIONS
If two or more Integrated models are installed
side by side where there is 51 mm or less of
space between the units, a heater kit is recom-
mended—TTDUAL for two tall units installed side
by side and BBDUAL for two base units or a
base unit and a tall unit installed side by side.
These optional components are available through
your Sub-Zero dealer.
TOP VIEW
CABINETS
635
mm
686 mm 914 mm
OR
Installation without side panels
Installation with side panels
Installation of two units side by side
Installation at end of run
MINIMUM 16 mm SIDE PANELS
CABINETS
OR
635
mm
686 mm 914 mm
TOP VIEW
CABINETS
OR
635
mm
1372 mm 1829 mm
MINIMUM 16 mm SIDE PANELS
CABINETS
OR
635
mm
686 mm 914 mm
ACCESSORIES
Optional accessories
are available
through your
Sub-Zero dealer.