PLANNING INFORMATION
Review the Overall Dimensions and Installation
Specifications illustrations for your Wine Storage
model on the following pages. These specifica-
tions cover all the details you need to know
about space allocation and placement of electri-
cal, whether the models are overlay, stainless
steel or integrated.
All Wine Storage models must be installed so
that the door can open a minimum of 90˚ or you
will have problems pulling the wine shelves out.
Refer to the door clearance and door swing
information.
For corner installations, you need allow for a
minimum 76 mm filler so the door can open to
90˚. If you are using larger handle hardware, you
will also need to take that into account.
For a maximum 90˚ door opening, use the door
stop built into the hinge system of Model I427.
An optional 90˚ door stop kit for Model I430 is
available from your Sub-Zero dealer.
If you will be connecting the unit to a home
security system, you must allow a minimum of
914 mm of the system‘s wiring to be routed in
the electrical area designated for your model.
IMPORTANT NOTE: The anti-tip bracket must be
installed to prevent the unit from tipping
forward.
DUAL INSTALLATIONS
If you are installing a Wine Storage unit next to
an existing Sub-Zero unit, you may have to allow
for a filler strip.
If you are installing a Model I427 or I427R Wine
Storage unit next to an existing Integrated
Sub-Zero unit, with 51 mm or less between the
units, an optional heater kit (BBDUAL or
TTDUAL) will need to be installed to prevent
moisture from forming between the units. This
optional kit is available through your Sub-Zero
dealer.
ELECTRICAL REQUIREMENTS
International models from the factory designed
without a transformer require a 220/240 V AC,
50/60 Hz electrical supply, fused at the correct
rating for the unit. If required by local or national
codes, the power cord can be easily replaced
using the power inlet device.
International models using a factory installed
transformer require a 220/240 V AC, 50/60 Hz
electrical supply, fused at the correct rating for
the unit. These models will come equipped with
Schuko power cords. The power cord may need
to be replaced depending on local and national
codes. The USA power cord that is supplied with
the product must be disconnected with the
appropriate transformer output to be connected
in its place.
IMPORTANT NOTE: The electrical outlet must
be grounded. The outlet must be flush with the
back wall. Refer to the Installation Specifications
illustration for your model for exact placement.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
INSTALLATION
Refer to the
installation instruc-
tions shipped with
each Sub-Zero
product for detailed
specifications.
ACCESSORIES
Optional accessories
are available
through your
Sub-Zero dealer.