23
Models 345, 346, 349, 355 Important: To the Operator
CO
2
Out Indicator
AUTO MODE AUTO
OK SYRUP OK
CO2- OUT WATER-OK
On the L CD, if the word “OUT” appears next to the
word “CO2” it indicates a lack of CO2 being supplied to
the freezer. The product light will also flash and a
warning tone will sound. This will continue until the
CO2 is replaced. If the CO2 is not replaced within one
minute, the machine will shut down and a fault
message will appear.
Water Out Indicator
AUTO MODE AUTO
OK SYRUP OK
CO2- OK WATER- OUT
On the L CD, if the word “OUT” appears next to the
word “WATER”, it indicates a lack of water being
supplied to the freezer. In addition, theproduct light will
flash and a warning tone will sound. This will continue
until the proper amount of water is supplied to the
freezer. If the water is not supplied within one minute,
the machine will shut down and a fault message will
appear.
Audio Alarm Silencer
The audio alarm will be disabled if the ALARM
SILENCE key is pressed. If a new fault or fault
condition occurs or the system mode changes, the
audio alarm will be re-enabled automatically. If the
audio alarm is silenced for greater than 30 minutes
without correcting the fault, it will be re-enabled
automatically.
Product Light
When the light is flashing, it indic ates that the product
is not at serving viscosity. This will occur during the
initial freeze down, a defrost cycle and a FAULT
condition and dur ing power saver modes.
Sampling Valve
The sampling valve is located behindthe front driptray.
The sampling valve is used to obtain a b rix reading.
Daily Procedures
The following procedure should be performed daily.
Remove the splash shield, front drip tray and center
drip pan. Take these parts to the sink and brush-clean
them. Re-install the parts onto the freezer.