Taylor 345/346/349/355 Freezer User Manual


 
355/355a/356
052840-58
11/12/13
YEL
BLK
YEL
BLK
RED/WHT
WHT
PRP/WHT
WHT
BLU/WHT
WHT
ORN
ORG/WHT
BRN
RED/BLK
BLK
LED
BARREL 2
LED
BARREL 1
RED/BLK
BLK
BLK
RED/BLK
BARREL 2
BARREL 1
BLK
BLK
BRN
RED
BLK
BLK
BLK
RED
BARREL
2
BIB
SWITCH
BARREL
2
HOPPER
FILL
SWITCH
THERMISTORS
PROBES
RIBBON CABLE SEE NOTE 2
WHT/BLK
BLK
LCD DISPLAY
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
WHT
PROXIMITY
SWITCHES
BARREL 2
BARREL 1
RIBBON CABLE SEE NOTE 2
RIBBON CABLE SEE NOTE 2
BARREL 1
KEYPAD
BARREL 2
KEYPAD
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY TOUCHING
GROUNDED UNIT BEFORE HANDLING SOLID STATE
COMPONENTS.
2. STRIPED WIRE ON RIBBON CABLES
MUST BE CONNECTED TO PIN 1
AT EACH END.
BRNBRN
BRN BRN
BARREL 2
SYRUP OUT
SWITCH
L1 L2
L2L1
LINE
LOAD
M
BLK
W2
BLK
BRN
ORG/WHT
ORN
PRP/WH
ORN/WHT
BRN
WHT
ORN
ORNBLK
BLK
WHT/BLK
32 1 4
H2O
PRESSURE
SWITCH
PRP/WHT
PRP/WHT
BRN
RED
BLK/YEL
BRN
YEL
BLK
YEL
BLK
M
FAN
WHT
BLK
BLK
BLK
WHT
BRN
PRP
PRP
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
RED
BLK
C02
PRESSURE
SWITCH
BARREL
1
HOPPER
FILL
SWITCH
BARREL
1
BIB
SWITCH
BARREL 1
SYRUP OUT
SWITCH
HPCO
L1
BLK
BLK
WHT/BLK
BLK
WHT
YEL
WHT
WHT
BLK
BLK
BLK
RED
BLK
BLK
WHT/BLK
3
6 1
BEATER MOTOR WIRING
YEL WHT
WHT/BLK
BLK/WHT
BLK/WHT
M
WHT
BLK
CARBONATOR FILL SWITCH
WHT
BLK/WHT
WHT
WHT
WHT/BLK
WHT
C NO C NO
BRN
BLK
BLU
BRN
BLK
BLU
BRN
BLU
RED
RED
BLU
15A FUSE
GROUND FRAME
SECURELY
BARREL
2
DEFROST
SOLENOID
RED/WHT
WHT
BLK
BLK
BARREL 1
SAMPLER SWITCH
(PUSHBUTTON-OPTIONAL)
BLK
BLK
BARREL 2
SAMPLER SWITCH
(PUSHBUTTON-OPTIONAL)
P.O.P.
DISPLAY
WHT
L2
RED
3 2
RED/BLK
FAN MOTOR
RUN CAPACITOR
USED WITH AIR
COOLED UNITS ONLY
BLK
BLK/WHT
6
1
(SEE FIG.1 IF REMOTE CARBONATOR)
OPTIONAL
CONTROL SWITCH
SPST
N L3
GRN
GRN/YEL
GRN/YEL
GRN/YEL
OPTIONAL
OPTIONAL
COMPRESSOR
CONTACTOR
L3
T3
BLK
BLK
GRN/YEL
BLK
GRN/YEL
GRN/YEL
WHT
WHT
LEESON
2
4 1
YEL WHT
WHT/BLK
COMPRESSOR
T2
L1
L2
COMPRESSOR
CONTACTOR
COMPRESSOR
CONTACTOR
T1
CARBONATOR
PUMP
CCW ROTATION
FROM LEAD END
M
BLK
CARBONATOR
FILL SWITCH
WHT
BLK/WHT
L1
2
1
BLK
3
WHT
BLK
BLK
BLK
WHT
GRN/YEL
BLK
WHT
GRN/YEL
N
LOW H2O PRESSURE
INDICATOR LIGHT
H2O
PRESSURE
SWITCH
REMOTE CARBONATOR WIRING
GRN/YEL
FIG. 1
GRN/YEL
CONTROL
ENCLOSURE(S)
1 2
1211
PRIMARY
SECONDARY
BEATER MOTOR
BARREL
1
LIQ. LINE
SOLENOID
COMP.
CONT.
COIL
BARREL
1
H20 SOL.
BARREL
1
SYR.SOL.
BARREL
1
CO2 SOL.
BARREL
2
CO2 SOL.
BARREL
2
H20 SOL.
BARREL
2
LIQ. LINE
SOLENOID
BARREL
2
SYR.SOL.
BARREL
1
DEFROST
SOLENOID
43 21
12
J1
J10 J11
J7
J9
J5
J6
J4
J3
J2
J6
CONTROL PCB A.
EMI FILTER
INTERFACE PCB A.
123 45 678 1 2
65 43 2 17
1 234
J14
J12J15J11
J5 J3 J1J4
J2
J10J9
L1
6 543 2 1765 43 217654 32 176 54 32 1
123 45 678
L2
J16 J13
J8
W1
123 4
J7
43 21
5 3 1
W1
MAGNATEK-CENTURY
PUMP
X1
A B
CONTROL
TRANSFORMER
1
11
2
12
EMPTY
EMPTY
EMPTY
EMPTY - H20 PRESSURE SWITCH ACTIVE/JUMPER - H20 PRESSURE SWITCH BYPASSED
EMPTY
SERVICE/TEST ONLY
4 3
6 5
8 7
910
INTERFACE PCB A. W1 JUMPER BLOCK DETAIL
JUMPER BLOCK SHOWN ABOVE WOULD INDICATE A UNIT CONFIGURED
AS A MODEL 355, AIR COOLED WITH A H20 PRESSURE SWITCH.
OUT
BRN OUT
PCB A.
IN IN
OUT