Taylor 345/346/349/355 Freezer User Manual


 
346
053566-40
11/12/13
YEL
BLK
YEL
BLK
RED/WHT
WHT
BLK
BLK
BLU/WHT
WHT
ORN
ORG/WHT
BRN
RED/BLK
RED/BLK
BLK
BLK
RED/BLK
BARREL 2
BARREL 1
BLK
BLK
BRN
RED
BLK
BLK
BLK
RED
BARREL
2
BIB
SWITCH
BARREL
2
HOPPER
FILL
SWITCH
THERMISTORS
PROBES
RIBBON CABLE SEE NOTE 2
WHT/BLK
BLK
LCD DISPLAY
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
WHT
PROXIMITY
SWITCHES
BARREL 2
BARREL 1
RIBBON CABLE SEE NOTE 2
RIBBON CABLE SEE NOTE 2
BARREL 1
KEYPAD
BARREL 2
KEYPAD
BRNBRN
BRN BRN
BARREL 2
SYRUP OUT
SWITCH
L1 L2
L2L1
LINE
LOAD
M
BLK WHT
W2
BLK
BRN
ORG/WHT
ORN
ORG/WHT
BRN
WHT
ORN
ORNBLK
BLK
WHT/BLK
41 1 4
H2O
PRESSURE
SWITCH
PRP/WHT
PRP/WHT
BRN
RED
BLK/YEL
BRN
YEL
BLK
YEL
BLK
BLK
BLK
WHT
BRN
PRP
PRP
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
RED
BLK
BLK
BLK
C02
PRESSURE
SWITCH
BARREL
1
HOPPER
FILL
SWITCH
BARREL
1
BIB
SWITCH
BARREL 1
SYRUP OUT
SWITCH
LEFT
HPCO
L1
N
BLK
WHT
WHT
WHT/BLK
WHT
WHT
YEL
WHT
WHT
BLKBLK
BLK
RED
BLK
BLK
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
WHT/BLK
WHT/BLK
WHT/BLK
YEL
GRN/YEL
WHT/BLK
M
BLK
WHT
BLK
BLK
WHT
M
WHT
BLK
RED/WHT
WHT
WHT
WHT
RED
WHT
BLK/WHT
BLK
BLK
RIGHT
HPCO
WHT/BLK
WHT
GRN/YEL
WHT
WHT
GRN/YEL
WHT
GRN/YELL
BLU/WHT
BRN
BLK
BLU
BRN
BLK
BLU
RED
LED
BARREL 2
BLK/WHT
RED
BLU
LED
BARREL 1
WHT
WHT
BLU
RED
M
BLK BLK
CARBONATOR FILL SWITCH
WHT
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY TOUCHING
GROUNDING UNIT BEFORE HANDLING SOLID
STATE COMPONENTS.
2. STRIPED WIRE ON RIBBON CABLES
MUST BE CONNECTED TO PIN 1 AT
EACH END.
RIGHT
COMPRESSOR
CONTACTOR
RIGHT
COMPRESSOR
FIG.2
RIGHT
COMPRESSOR
CONTACTOR
GROUND FRAME
SECURELY
15 A
FUSE
BLK
GRN/YEL
WHT
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
COPELAND COMPRESSOR WIRING
1
2
5
4
WHT
BRN
BLK
BRN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHT(120 VOLTS; 220V-50Hz)
BLK(230 VOLTS)
BLK
BLU
START
1
3
MAIN
2
4
2C
THERMAL
O.L.
EXTRA
MAIN
6
5
RED 50 HZ
BLK 60 HZ
WHT COM
BRN
BRN
CAP
208/240 50/60 HZ
GE BLOWER MOTOR SCHEMATIC
FIG. 3
WHT
MAGNATEK-CENTURY
5
6 1
LEESON
2
4 1
BEATER MOTOR WIRING
YEL WHT
WHT/BLK
YEL WHT
WHT/BLK
T1 OR BLU
T8 OR RED
THERMAL OL
BRN
YEL
WHT/BLK
4
2
WHT
T4 OR YEL
T5 OR BLK
A
P2 OR BRN
P1 OR PUR
MAIN
START
5
1
GE/RBC BEATER MOTOR WIRING
CWLE-RED OR T8 INTERNAL ON #A, BLACK OR T5 INTERNAL ON #5
1
2
3
FIG.1
FIG.2
1 2
1211
PRIMARY
SECONDARY
LEFT BEATER MOTOR
FIG.1
BLOWER
(FIG 3)
BARREL 1
COMP.
CONT.
COIL
BARREL
1
H20 SOL.
BARREL
1
SYR.SOL.
BARREL
1
CO2 SOL.
BARREL
2
CO2 SOL.
BARREL
2
H20 SOL.
BARREL
2
SYR.SOL.
BARREL 1
DEFROST
SOLENOID
43 21
12
J1
J10 J11
J7
J9
J5
J6
J4
J3
J2
J6
CONTROL PCB A.
CONTROL
SWITCH
SPST
EMI FILTER
LEFT
COMPRESSOR
FIG.2
LEFT
COMPRESSOR
CONTACTOR
T1
L2
T2
L1
INTERFACE PCB A.
123 456 78 12
65 43 217
12 34
J14
J12J15J11
J5 J3 J1J4
J2
J10J9
L1
65 43 2176 54 32 176 543 2 176 5 432 1
123 456 78
L2
J16 J13
J8
W1
123 4
J7
43 21
5 3 1
W1
LEFT
COMPRESSOR
CONTACTOR
RIGHT BEATER MOTOR
FIG.1
T1
L2
T2
L1
COMP.
CONT.
COIL
BARREL 2
DEFROST
SOLENOID
BARREL 2
X1
A B
PUMP
1
11
2
12
EMPTY (JUMPER USED FOR W.C. ONLY, SOFTWARE VER. 2.04).
EMPTY - H20 PRESSURE SWITCH ACTIVE/JUMPER - H20 PRESSURE SWITCH BYPASSED
EMPTY
SERVICE/TEST ONLY
4 3
6 5
8 7
910
INTERFACE PCB A. W1 JUMPER BLOCK DETAIL
JUMPER BLOCK SHOWN ABOVE WOULD INDICATE A UNIT CONFIGURED
AS A MODEL 346, AIR COOLED WITH A H20 PRESSURE SWITCH.
EMPTY
EMPTY (JUMPER USED FOR MODEL 346, SOFTWARE VER. 2.04).
C
NO
C
NO
OUT
BROWN OUT
PCB A.
IN IN
OUT
CONT.
TRANS.