27
Models 345, 346, 349, 355 Operating P rocedures
Place the draw handle slide over the opening in the
draw handle and the pivot pin. Secure the assembly
with screws.
Figure 20
Insert the spring into the front of the door spout.
Figure 21
Place the threaded cap on the end of the draw valve
cavity. Turn the cap clockwise until it is secure.
Figure 22
Step 4
Install the prime plug. Place the two o-rings on the
prime p lug and lightly lubricate.
Figure 23
Step 5
Place the large o-ring into the door groove and lightly
lubricate.
Figure 24
Note: Every three months, discard the o-rings and
install new o-rings.