Models 345, 346, 349, 355 To t he I nstaller
120828
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
DO NOT operate this freezer with larger fuses
than specified on the unit data label. Failure to follow
this instruction may result in electrocution or damage
to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frameby the authorized installer. Theinstallation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
Stationary appliances which are not equipped
with a power cord and a plug or another device to
disconnect the appliance from the power source must
have an all-pole disconnecting device with a contact
gap of at least 3 mm installed in the external
installation.
Appliances that arepermanently connectedto
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected or not
used for long periods, or during initial installation, shall
have protective devices such as a GFI, to protect
against the leakage of current, installed by the
authorized personnel to the local codes.
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or other equivalent synthetic
elastomer-sheathed cord (Code designation 60245
IEC 57) installed with the proper cord anchorage to
relieve conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
Beater Rotatio n
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures should be
performed by a trained service technician.
To correct the rotation on a three- phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single- phase unit, change the
leads inside the beater motor. (Follow the diagram
printedonthemotor.)
Initial Freezing Cylinder Cleaning
Due to the types of products used in FCB equipment,
it is imperative that the freezing cylinder and t he inlet
tube be thoroughly brush cleaned, rinsed, and
sanitized before running any product.
Prepare a cleaning solution, using 2 oz. of liquid
detergent in 2 gallons of warm water. Using this
solution, brush clean the freezing cylinder and the inlet
tube. Rinse the freezing cylinder and the inlet tube with
clean water and then sanitize, using the sanitizing
procedures outlined in this Operator Manual, starting
on page 29.
Refrigerant
In consideration of our environment, Taylor
uses only earth friendly HFC refrigerants. The HFC
refrigerant used in this unit is R404A. This refrigerant
is generally considered non-toxic and non-flammable,
with an Ozone Depleting Potential (ODP) of zero (0).
However , any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow f or normal expansion.