Henny Penny 600 Fryer User Manual


 
Model 500/600
DO NOT PULL THIS RING. SEVERE BURNS FROM
THE STEAM WILL RESULT. (SEE FIGURE 3-1)
Indicates the pressure inside the frypot; Figure 3-1
An electromechanical device that allows pressure to be held in the
frypot; the solenoid valve closes at the beginning of the Cook Cycle
and automatically opens at the end of the Cook Cycle; if this valve
becomes dirty or the teflon seat nicked, pressure will not build, and the
valve must be repaired per Technical Manual
A two-way ball valve that is normally closed; turn the handle to drain
the peanut oil from the frypot into the filter drain pan
DO NOT OPEN THE DRAIN VALVE WHILE FRYPOT IS
UNDER PRESSURE. HOT PEANUT OIL WILL
EXHAUST, AND SEVERE BURNS WILL RESULT.
Provides protection for the frypot in the event an Operator inadvertently
drains the peanut oil from the frypot while the COOK/PUMP switch is
on; the switch automatically shuts off the heat when the drain valve is
opened
Collection point for the condensation formed within the steam exhaust
system; remove and empty periodically
A spring loaded latch that provides a positive latch to hold the lid
closed; this latch, along with the spindle assembly and lid gasket,
provides a pressure sealed frypot chamber
3-1. OPERATING
COMPONENTS
(Continued)
Safety Relief Valve Ring
Pressure Gauge
Solenoid Valve
Drain Valve
Drain Interlock Switch
Condensation Drain Pan
Lid Latch
3-2 803