Henny Penny 600 Fryer User Manual


 
Model 500/600
If any of the product settings do not match original values, the following
message is displayed (with one or more of the product numbers
blinking):
“10: PROD’S 123456”
“10: DO NOT MATCH”
“10: ORIG. VALUES”
In this case, the blinking numbers indicate which products do not match
original settings. If the numbers 3 and 5 are the only numbers blinking,
then product #3 and product #5 each have at least one setting changed
from their factory preset values. Products 1, 2, 4, and 6 are confirmed
to exactly match their original settings.
The second item in D 10 identifies how many items in CF
A
Programming Mode have been changed from their original values.
These Chick-fil-A settings mainly deal with special Chick-fil-A
controller features like oil wear, heat-up monitoring, new oil
compensation, oil idle compensation, drop detection, amps and voltage
alarms, and Clean-out Mode.
If all items in CFA Prog Mode match their original, factory preset
values, the following report is made:
“10: ALL CFA ITEMS”
“10: MA
TCH”
“10: ORIG. VALUES”
If any of the items in CFA Prog Mode do not match their original
values, the following message is displayed (with the actual number of
changed items):
“10: 2 CFA ITEMS”
“10: DO NOT MATCH”
“10: ORIG. VALUES’
A similar report is made for Special Program Mode. Special Program
(SP) Mode settings deal with °F/°C display, speaker tone and volume,
Melt and Idle Modes, and how the product buttons function (start cook
or merely select product).
“10: ALL SP ITEMS” “10: 1 SP ITEMS “
“10: MATCH “ “10: DO NOT MATCH “
“10: ORIG. VALUES “ “10: ORIG. VALUES “
5-3. DIAGNOSTIC MODE
DETAILS (Continued)
303 5-25