Henny Penny 600 Fryer User Manual


 
Model 500/600
3-5. WARNINGS AND
ERROR MESSAGES (Continued)
ERROR CODES
DISPLAY CAUSE CORRECTION
“E-5” Controls sensing 405°F Have heat components and temperature probe
“FRYER TOO or above checked
HOT”
“E-6” (A or B) Faulty temperature probe or Have temperature probe and connection
“FRYER TEMP connection checked
SENSOR
FAILED”
“E-10” Peanut oil temperature too hot, Reset high limit per Operating Components;
“HIGH LIMIT drain valve opened while heat was Section; check peanut oil temperature for
TRIPPED” on, or faulty high limit overheating; have heat components checked if
high limit continues to trip
“E-15” Drain is open or faulty microswitch Close drain; have drain microswitch checked
“DRAIN IS if error code persists
OPEN”
“E-25” Wrong or faulty elements or wiring Have electrical supply, wiring, and elements
“HEAT AMPS problem. checked
WERE TOO
HIGH”
(500 fryer only) Because of the seriousness of this error code,
turn the COOK/PUMP switch OFF and back
to COOK to cancel.
“E-26” Faulty contactors or PC board Have the contactors and PC board checked
“HEAT AMPS
ARE
LOCKED ON”
(500 fryer only) This error code could be displayed even with
the COOK/PUMP switch turned OFF. Unplug
fryer or shut off the wall circuit breaker to
disconnect electrical power to fryer.
E-41” Memory scrambled; an individual Turn the COOK/PUMP switch OFF and back
“SYSTEM product program may be scrambled; to COOK; if error code persists, have the PC
DATA LOST” ex: “E-41 -2- DATA LOST”; this board checked or re-initialized
means product #2 program is
scrambled
E-41” Memory scrambled; an individual Turn the COOK/PUMP switch OFF and back
“SYSTEM product program may be scrambled; to COOK; if error code persists, have the PC
DATA LOST” ex: “E-41 -2- DATA LOST”; this board checked or re-initialized
means product #2 program is
scrambled
3-12 205