Model 500/600
Problem Cause Correction
HEATING OF PEANUT OIL SECTION (Continued)
Peanut oil heating slowly
• Low or improper amps • See Infomation Mode 16
for present amperage; or
see Information Modes 4, 5, 6,
7, 8, 9, for more information
on this problem; Diagnostic
Mode D 4 gives present day’s
heating performance
• Low or improper voltage • See Diagnostic Modes D 3 &
D 4 for present day’s voltage
and heating performance; or
see Information Modes 4, 5, 6,
7, 8, 9, and 15 for more informa-
tion on this problem
• Weak or burnt out • See Diagnostic Modes D 4;
elements (elec. model) see if “CHECK
COILS, CONTACTORS
• Burnt or charred connectors AND WIRING” shows on
display; if so, have fryer
• Faulty contactor (electric models) checked by a certified service
technician
• Wire(s) loose • Have wires tightened
• Supply line too small - low • Increase supply line size;
gas volume (gas models) refer to installation
instructions
• Improper ventilation • Refer to installation
system (gas models) instructions
803 5-9