Henny Penny 600 Fryer User Manual


 
Model 500/600
3-4. DIAGNOSTIC MODE
AND SPECIAL
FUNCTIONS
(Continued)
Manual Mode
This allows the Operator to quickly program a time and temperature for
nonstandard products that are not on the menu card. This is to be a
temporary setting and disables most of the advanced features of the
controls. To enter Manual Mode:
1. Once out of the Melt Cycle, press then .
2. Use to set cook time.
3. Press and use to set temperature.
4. Press to start Manual Mode. Display shows “MANUAL”
and you start a Cook Cycle by pressing .
5. Press to exit Manual Mode.
Status Mode
Pressing during idle time, allows Operator to view:
a. The temperature of the peanut oil
b. The temperature setpoint and any offset
c. The average peanut oil temperature during last Cook Cycle
d. The rate of temperature rise or fall
e. Date and time
Pressing during a Cook Cycle allows the Operator to view:
a. The temperature of peanut oil, plus the degrees and rate the load
compensation has affected the Cook Cycle (slows down or
speeds up the timer)
b. The cooking step, the time left in Cook Cycle, setpoint tempera-
ture and whether pressure is on or off
c. The average peanut oil temperature in Cook Cycle so far
d. The rate of temperature rise or fall
e. Date and time
After 5 seconds, the control exits the Status Mode and the pressure
fryer returns to normal operation.
Peanut Oil Filter Enforcement
Prevents the Operator from exceeding the set number of Cook Cycles
before filtering the peanut oil. The number in the center of the display
shows how many Cook Cycles remain before filter lockout occurs. For
example, “5X” means the Operator can run 5 more Cook Cycles
before filtering. This function cannot be bypassed.
803 3-9