3-4. DIAGNOSTIC MODE
AND SPECIAL
FUNCTIONS
(Continued)
Information Mode
This mode gathers and stores historic information on the fryer and
Operator performance. Press and at the same time and
“*INFO MODE*” shows on display. Press or to access the
steps and press to view the statistics within each step.
Information Mode is intended for technical use, but the Operator can
view the following information:
1. E-LOG - last 10 errors and time they occurred
2. P-LOG - time of last 10 power-ups
3. HEAT-UPS - time of day and maximum heating rate (°/second) for
the last 10 heat-ups
4. COOK DATA - information on the last Cook Cycle
5. TODAY’S DATA - data since the start of day (not including the
last Cook Cycle)
6. PREV-DAY-SUN - creates a log of the last 7 days, using the
information in TODAY’S DATA.
7. 7-DAY TOTALS -totals the information from the last 7 days
8. OIL DATA - information on the current peanut oil, not including
today’s cooking information
9. PREV OIL DATA - information on last batch of peanut oil
10. INP - provides test of fryer inputs
11. OUTP - shows the state of heater and pressure
12. POT TMP - temperature of peanut oil
13. CPU TMP - temperature of PC board
14. ANALOG - status of controller’s a-to-d converter
15. AC VOLTS - status of the line voltage to fryer
16. AMPS (Electric models only) - the present amp readings to
heaters.
See Information Mode Details Section.
3-10 303