Henny Penny 600 Fryer User Manual


 
Model 500/600
Problem Cause Correction
PRESSURE SECTION (Continued)
Pressure does not Not enough product in fryer Place proper quantity of
build or product not fresh fresh product within frypot to
generate steam
Metal shipping spacer not Remove shipping spacer;
removed from deadweight see Unpacking Section
Lid open or not latched Close and latch lid
Solenoid valve leaking or Have solenoid valve checked or
not closing cleaned
Deadweight assembly leaking Have deadweight assembly
repaired
Pressure not programmed See Diagnostic Mode D 10;
if pressure settings have been
changed, have the controls
reintialized
Lid gasket leaking Reverse gasket or lid needs
adjusted
Safety relief valve leaking. Check and replace if necessary
FILTER SYSTEM SECTION
Filter motor runs Pump clogged Have pump cleaned
but pumps peanut oil
slowly Filter line connection Tighten all filter line
loose connections
Solidified peanut oil Clear all filter lines of solidified
in lines peanut oil
Filter switch on, Defective COOK/PUMP switch Have switch checked
motor does not run
Defective motor Have motor checked
Motor thermal protector tripped Reset thermal protector
per Filter Pump Motor
Thermal Protector Section
803 5-7