Henny Penny 600 Fryer User Manual


 
Model 500/600
The filter pump motor is equipped with a manual reset button in case the
motor overheats. This reset button is located in the rear of the motor.
The filter motor is located on the rear of the fryer. Wait about 5 minutes
to allow motor to cool before attempting to press the reset button. It
takes some effort to reset, and a screwdriver can be used to help reset
the button. Figure 3-9.
To prevent burns caused by splashing shortening, turn
the unit’s main power switch to the OFF position before
resetting the filter pump motor’s manual reset protection
device.
Change the filter envelope daily, or whenever it becomes clogged with
crumbs. Proceed as follows:
1. Move the COOK/PUMP switch to OFF.
2. Remove and empty the condensation drain pan.
3. Disconnect the filter union and remove the filter drain pan from
beneath the frypot. Figures 3-10 & 3-11.
This union could be hot! Use protective cloth or glove,
or severe burns could result.
If the filter pan is moved while full of peanut oil, use
care to prevent splashing, or burns could result.
4. Lift crumb basket and screen assembly from the drain pan.
3-11. FILTER PUMP MOTOR
THERMAL PROTECTOR
3-12. CHANGING THE
FILTER ENVELOPE
803 3-23
Figure 3-9
Figure 3-10
Figure 3-11