Henny Penny 600 Fryer User Manual


 
Model 500/600
3-4. DIAGNOSTIC MODE
AND SPECIAL
FUNCTIONS
Diagnostic Mode
To view summaries of the fryer and Operator performance, press
then . Press to view the following functions:
D1 - Adjust product color for all products (not individually)
D2 - The age of the peanut oil and life remaining
D3 - Outlet voltage monitoring
D4 - Fryer’s heating performance
D5 - Slow or oversized product batches
D6 - Cook Cycles started before temperature recovered
D7 - Cook Cycles stopped more than 10 seconds before end of
cycle
D8 - Cook Cycles not ended within 20 seconds after expired time
D9 - Number of times loading product took too long
D10 - Programmed variables changed by Operator
On several of the screens you may have to press or to
respond to questions asked.
Press at any time to exit and return to normal operation.
See Diagnostic Mode Details Section.
Peanut Oil Life Function
Based on the number of Cook Cycles of specific products and the
amount of time the fryer idles, the controls tell the Operator when to
change the peanut oil.
“CHANGE OIL SOON” shows on the display when the controls
determine it’
s time to change peanut oil. Unless the peanut oil is smok-
ing or has a burnt flavor, the peanut oil does not need to be changed
before this message shows on the display. After cleaning the frypot,
using the Clean-Out Mode ( see Cleaning the Frypot Section), this
function resets.
Language Selection
Pressing then allows the Operator to choose to have the
information on the display in English or Spanish.
3-8 1203