Problem Cause Correction
POWER SECTION
With COOK/PUMP Switch Open circuit Check to see if fryer is plugged
in COOK position, fryer is in
completely without power
Check wall circuit breaker or
fuse
Have a qualified service techni-
cian check power supply and
COOK/PUMP switch
PRESSURE SECTION
Pressure will not Exhaust line from solenoid Turn unit off and allow fryer to
exhaust at end of valve to exhaust tank cool to release pressure from
cooking cycle. clogged frypot; have all pressure lines,
exhaust stacks, and exhaust
tank cleaned
Solenoid valve clogged Have solenoid checked and
cleaned
Operating pressure too high
Deadweight clogged Turn unit off and allow fryer to
cool to release pressure from
frypot; remove deadweight and
clean, per Cleaning the Dead-
weight Valve Section.
Exhaust line to stack clogged Clean exhaust line to stack
DO NOT OPERATE UNIT IF PRESSURE GAUGE SHOWS HIGH PRESSURE CONDITIONS.
SEVERE INJURIES AND BURNS WILL RESULT. IMMEDIATELY PLACE THE POWER/
PUMP SWITCH IN THE OFF POSITION, WHICH RELEASES THE PRESSURE BY ALLOW-
ING THE UNIT TO COOL. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH
PRESSURE HAS BEEN FOUND AND CORRECTED.
5-6 803