Sterling A0567659 Blender User Manual


 
SGB Batch Blender with Mitsubishi Controller Page 107 of 118
introduced material into the weigh hopper,
adjust the Maximum Empty Weight of the
hopper.
The weight filter is the specialized filter
algorithm that smoothes erroneous load cell
readings. The signal will be filtered more if this
value is increased and less if decreased. This
setting should not be modified except by the
developer except under unusual
circumstances.
Feed Algorithm This screen allows the user to configure how the
Options Screen blender metering algorithm works. The user can
adjust the Initial percentage of Target to Meter, the
Allowed Underfeed value, the number of retries
before Double Gate Time, the allowed Weight/Sec
Drop, and the Out of Material retry limit.
Weight Filter
Weight/Sec.
Filter
Adjust the limit for
“Hopper Over Max
Weight”
Adjust Settle Time
Go back to Sterling
Engineering Only
Directory
Go back to Sterling
Engineering Only