SGB Batch Blender with Mitsubishi Controller Page 81 of 118
6-5 Mechanical
The mechanical design of the blender is very simple and very little maintenance is
required. The only moving parts are the metering gates, weigh hopper dump
valve and mixer agitator. The following maintenance is suggested:
Daily
• Inspect blender for any loose parts-tighten them immediately.
• Verify quality of compressed air supply.
• Verify mixer door is properly latched.
Weekly
• Inspect metering gates for proper operation.
Monthy
• Inspect air regulator and air safety circuits, if equipped.
• Recalibrate blender only if necessary.
Typical Model SGB Assembly Overview