Page 112 of 118 SGB Batch Blender with Mitsubishi
Controller
12-2 Passwords
User Password “5413”
Maintenance Password “3145348”
CAUTION! Maintenance password should only be supplied
to qualified
personnel! The program can be
compromised.
12-3 Default Values (factory defaults shown):
SGB BLENDER CONFIGURATION PARAMETERS
Model Number/Type
SGB-450 SGB-900 SGB-2500 SGB-4000 SGB-5000
RECIPE FORMAT
Recipe Entry Mode
QUICK SET
Batch Size
3.5 7 35
Inventory Shutdown
0
Batch Ready Mode
AutoStart Mode
Enabled
REPORT SETUP
Blender Number
1
SCALE CALIBRATION PERFORM A SCALE CALIBRATION ON ALL MANUFACTURED UNITS
DIRECT SCALE
READOUT
LOG THESE VALUES AFTER THE SCALE CAL WITH THE ORDER
INFORMATION
FEEDER CALIBRATION
Hop1 wt/sec
1 2 2 4
Hop2 wt/sec (WITH
STROKE LIMITER)
0.25 0.5 0.5
Hop3 wt/sec (WITH
SQUARE GATE)
1 4 8
Hop4 wt/sec (WITH
STROKE LIMITER)
0.25 0.5 0.5
Hop5 wt/sec (WITH
STROKE LIMITER)
Hop6 wt/sec (WITH
STROKE LIMITER)
0.25 0.25
MIXER AND DUMP SETUP
Mixing Time
4 6
Remix Time
0
Dump Time
4 6 5