3M 40800 Food Saver User Manual


 
26
700r-NA
2011 July
Figure 7-14 – Controls, Valves and Switches
Note – The case sealer has a circuit breaker located
in the electrical enclosure on the lower left side
of the machine frame. If circuit becomes over-
loaded and circuit
breaker trips, unplug the
machine electrical
cord and determine cause
of overload. After two minutes, remove the
electrical control box cover and reset the circuit
breaker by pressing the "Reset" button and
then the "Start" button on the circuit breaker.
Replace the control box cover, plug machine
electrical cord into outlet and restart machine
by pressing green "On" button.
2. Main Air "On/Off" Valve/Pressure Regulator/
Filter – Figure 7-15
This set of pneumatic components controls,
regulates and lters plant air supply to the two
separate control circuits of the case sealer.
"On/Off" Valve – "On" turn to "SUP" – "Off"
turn to "EXH". Note – Turning air supply "Off"
automatically bleeds air pressure from the case
sealer air circuits.
1. Electrical "On/Off" Switch
The box drive belts are turned on and off
("Off" button is red) with the electrical switch on
the side of the machine frame.
Always turn the air "Off" when machine is not in use,
when servicing the machine, or when connecting or
disconnecting air supply line.
NoteThe air valve has provisions for Lockout/
Tagout according to plant regulations.
Figure 7-15 – "On/Off" Valve/Regulator/Filter
Note:
Function of these
Controls are Explained
Below.
9
8
2
7
1
6
5
4
3
10
Mechanical Latch,
Upper Drive Assembly
Main Air Pressure
Gauge
Main Air On/Off Valve/
Pressure Regulator/Filter
Air Pressure Regulator,
Top Drive Assembly Force
Electrical On/Off Switch
Air Pressure Regulator,
Centering Guide Force
Centering Switch
Box Centering Guides
Raising Switch,
Upper Drive Assembly
Emergency
Stop Switch
Indicator,
Air Pressure
Filter
Regulator
Down
to Lock
Up to
Adjust
Air Supply
Connector
Air On/Off
Valve
7-INSTALLATION AND Setup (continued)