3M 40800 Food Saver User Manual


 
10-SAFETY DEVICES OF THE MACHINE
36
10.1 Blade Guards
Both the top and bottom taping units have a
blade guard (See Manual 2:
AccuGlide™ 3 Taping Heads - 2 inch).
2011 July
700r-NA
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot
and vehicle traf c.
WARNING
To reduce the risk associated with sharp
blade hazards:
Keep hands and ngers away from tape
cutoff blades under orange blade guards.
The blades are extremely sharp.
WARNING
Figure 10-1
10.3 Electric System / Circuit Breaker
The electric system is protected by a ground wire
whose continuity has been tested during the nal
inspection. The system is also subject to insulation
and dielectric strength tests.
Important: The use of an extension cord is not
recommended. However, if one is needed for
temporary use, it must:
Have a wire size of 1.5mm diameter [AWG 16]
Have a maximum length of 30.5m [100 ft]
Be properly grounded.
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical enclosure on the side of the
machine frame just below the machine bed, the
circuit breaker has been preset and requires no
further maintenance.
1. Determine cause of overload and correct.
2. Plug in machine.
3. Press machine "On" (I) button to resume case
sealing.
Circuit Breaker
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
To reduce the risk associated with
mechanical and electrical hazards:
Allow only properly trained and quali ed
personnel to operate and service this
equipment.
WARNING
Important!
All adjustments and tape loading require that
the machine is stopped and the emergency
stop button is locked.
Main electric switch "OFF" (O). Severe injury to
personnel could result by lack of observing
these elementary rules
10.2 Emergency Stop Button
The box drive belts are turned on and off with the
electrical switch on the side of the machine frame.
The machine electrical supply can be turned off
by pressing the latching emergency stop switch.
To restart machine, rotate the emergency stop
switch clockwise to release the switch latch.
Restart machine by pushing the Start button
(Figure 10-1)
.