3M 40800 Food Saver User Manual


 
32
8.1 Description of the Working Cycle
After having closed the top aps of the carton,
the operator pushes it under the top infeed end
in order to avoid the opening of the top aps. Further
pushing causes the two top and bottom belts to
drive the box through the taping heads which
automatically seal the top and bottom seams.
The carton is then expelled on the exit conveyor.
8.2 Definition of Running Mode
The case sealer 700r has only one (automatic) oper-
ating mode with:
- The EMERGENCY STOP BUTTON unlocked
(Figure 8-1)
- The main start switch “ON” (I)
(Figure 8-2)
8.3.1 Normal Stop Procedure
When the main switch is turned OFF (O), the
machine stops immediately at any point of the
working cycle. The same thing happens in case
of electrical failure or when the machine is
disconnected from the mains.
8.3.2 Emergency Stop
The LATCHING EMERGENCY STOP BUTTON is
located on the top center of the machine
(Figure 8-1).
8-THEORY OF OPERATION
Figure 8-3
2011 July
700r-NA
E-Stop Location
Belt
Direction
Figure 8-1
Figure 8-2