49
Special Setup Procedure (continued)
Box Height Range – (Refer to Figure 13-11 / Section 7.4 / and Specif cations)
The operating range of the upper drive assembly can be adjusted to minimize its movement
(which increases the operating speed) and in conjunction with adjusting the bed height, to
change the range of box heights being sealed.
After establishing the minimum box height to be sealed, position the stop bumpers as follows:
1. Latch upper drive assembly in upper position, turn off air and electric.
2. Remove and relocate the stop bumper assembly to the desired position on both side columns. Be sure that
the stop bumpers are reassembled as shown and secure (See Figure 13-11 and Figure 15104).
3. Turn on the air and electrical power to the case sealer.
The upper taping head will now descend only part-way thus increasing operating speed.
700r-NA
2011 July
• To reduce the risk associated with mechanical and electrical hazards:
− Turn electrical and air supply off and disconnect before performing any adjustments,
maintenance or servicing the machine or taping heads
WARNING
• To reduce the risk associated with muscle strain:
− Use the appropriate rigging and material handling equipment when lifting or repositioning
this equipment
WARNING