Section 14 Starting the Project
If the project has been downloaded completely, the application can be started after the following
steps are completed:
1. Set the operating mode to Run-Mode (operating mode switch to position 5).
2. Connect the PLC and the Panel.
3. Press the Reset button on the Panel.
After switching the Panel on or pressing the Reset button, the Start-up picture appears on the
screen:
Press the “Next” key on the Panel, and PICT_1 will appear on the screen:
The inverse display area is an input field in which values can be entered using the numerical keys
(on the numeric Keyblock). After the entry is confirmed by pressing , the value that was entered
should appear in the output field above. (See the “Key Assignments” section in this chapter for
individual key descriptions.)
If the connection is not made between the PLC and the Panel, or if it is improperly made (cable
defective, wrong interface, etc.), the following message is displayed shortly after the Reset button
is pressed: