5. BASE SPECIFICATIONS PARAMETERS
II - 38
# Items Details Setting range (unit)
1114 mcrint Macro
argument
initialization
Select whether to clear statements other than
specified arguments by macro call. Also, select
whether to clear local variables by power-ON and
resetting.
0: Delete non-specified arguments by macro
call.
1: Retain non-specified arguments by macro
call.
2: Retain non-specified arguments by macro
call and clear local variables by power-ON
and resetting.
0/1/2
1115 thwait Waiting for
thread
cutting
Set the queue number during screw thread cutting
when the chamfering is not valid.
0 to 99
(Approx. 4 ms.)
Standard set value: 4
1116 G30SLM Invalidate
soft limit
(manual
operation)
Enable this function when disabling the soft limit
check function from the second to the fourth zero
point return by manual operation.
0: Enable soft limit
function.
1: Disable soft limit
function.
1117 H_sens Handle
response
switch
Switch the handle response mode when feeding
the handle.
0: Standard handle response
1: High-speed handle response
0/1
1118 mirr_A
(For L
system
only)
Not used.
1119 Tmiron
(For L
system
only)
Not used.
1120
(PR)
TofVal Change
macro
variable
Specify whether to change the macro variable (tool
offset) numbers for shape compensation and wear
compensation.
0: Do not change. (Conventional specifications)
1: Change the shape and wear compensation
variable numbers each for X, Z, and R.
0/1