6. AXIS SPECIFICATIONS PARAMETERS
6.4 Axis Specifications Parameters 2
II - 98
(SETUP PARAM 2. 8/8)
# Items Details Setting range (unit)
2086 exdcax External
deceleration
speed
Set the upper limit of the feedrate for each axis when
the external deceleration signal is valid.
This parameter is valid when the #1239 set11/bit6
external deceleration axis compliance valid is set to
1.
1 to 999999 (mm/min)
2087 syncnt Not used.
2088 bsax_sy Not used.
2089 bsax_pl Not used.
2090 plrapid Not used.
2091 plclamp Not used.
2092 plG0tL Not used.
2093 plG0t1 Not used.
2094 plG1tL Not used.
2095 plG1t1 Not used.
2096 crncsp Minimum
corner
deceleration
speed
Set the minimum clamp speed for corner
deceleration during the high-accuracy control mode.
Normally set "0".
0 to 1000000
(mm/min)
2102 skip_tL Skip time
constant linear
Set up a linear control time constant for variable
speed skip acceleration and deceleration.
The time constant is validated when LC (cutting feed
with linear acceleration and deceleration) or F
(acceleration and deceleration by software) is
selected in acceleration or deceleration mode
"#2003 smgst".
1 to 4000 (ms)
2103 skip_t1 Skip time
constant
primary delay
acceleration
and
deceleration
by software
second stage
Set up a primary-delay time constant for variable
speed skip acceleration and deceleration.
The time constant is validated when C1 (cutting feed
with primary delay) or C3 (exponential acceleration
and linear deceleration) is selected in acceleration or
deceleration mode "#2003 smgst".
When acceleration or deceleration by software is
selected, the second-step time constant is used.
1 to 5000 (ms)