13. AUXILIARY AXIS PARAMETER
II - 323
No. Name Details Setting range
Default
value
190 stpos2 Station 2
coordinate
value
191 stpos3 Station 3
coordinate
value
192 stpos4 Station 4
coordinate
value
193 stpos5 Station 5
coordinate
value
194 stpos6 Station 6
coordinate
value
195 stpos7 Station 7
coordinate
value
196 stpos8 Station 8
coordinate
value
197 stpos9 Station 9
coordinate
value
Set the coordinate value of each station when
non-uniform assignment is selected.
The station 1 coordinate value is fixed at 0.000
(machine coordinate zero point).
-99999.999 to
99999.999
(° or mm)
0.000
200 PSWcheck PSW
detection
method
This is a HEX setting parameter. Set bits without a description to their default
values.
bit FEDCBA98765 4 3 210
Default
value
00000000000 0 0 000
bit Position switch Meaning when "0" is set Meaning when "1" is set
0
PSW1
1
PSW2
2
PSW3
3
PSW4
4
PSW5
5
PSW6
6
PSW7
7
PSW8
The position switch
output is judged by the
machine position of the
command system.
The position switch
output is judged by the
machine FB position
(actual position).
8
9
A
B
C
D
E
F