10. PLC CONSTANTS
10.3 PLC Constants
II - 299
10.3 PLC Constants
(SETUP PARAM 6. 4/14)
# PLC device Item Details Setting range
6301
6348
R2800,2801
R2894,2895
PLC constant Set the value to be set in the data type R
register used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
–99999999
to 99999999
(SETUP PARAM 6. 5/14)
# PLC device Item Details Setting range
6349
6396
R4900,4901
R4994,4995
PLC constant Set the value to be set in the data type R
register used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
–99999999
to 99999999
10.4 Selecting the PLC Bit
(SETUP PARAM 6. 6/14) to (SETUP PARAM 6. 7/14)
# PLC device Item Details Setting range
6401
6402
6495
6496
R2900-Low
R2900-High
R2947-Low
R2947-High
Bit selection This is the bit type parameter used in the
PLC program (ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
Some of the parameters following #6449
may be fixed according to the usage
purpose.
Refer to the PLC Program Development
On-board Instruction Manual.
0: OFF
1: ON
(SETUP PARAM 6. 7/14) to (SETUP PARAM 6. 9/14)
# PLC device Item Details Setting range
6497
6498
6595
6596
R4400-Low
R4400-High
R4449-Low
R4449-High
Bit selection
expansion
This is the bit type parameter
(expansion) used in the PLC program
(ladder).
Even if the data is set in the R register
that corresponds to the PLC side when
this parameter is displayed‚ the screen
will not change. Enter a different screen
once‚ and then select this screen again.
0: OFF
1: ON