8. SPINDLE PARAMETERS
8.1 Spindle Base Specifications Parameters
II - 229
# Items Details Setting range (Unit)
3066 spdiv6 Magnification for
time constant
changeover speed
6
Set the acceleration/deceleration time
constant between the spindle
synchronization multi-step
acceleration/deceleration changeover
speed 6 (sptc6) to the spindle
synchronization multi-step
acceleration/deceleration changeover
speed 7 (sptc7) as a magnification in
respect to the spindle synchronization
acceleration/deceleration time constant
(spt).
0 to 127
3067 spdiv7 Magnification for
time constant
changeover speed
7
Set the acceleration/deceleration time
constant for the spindle synchronization
multi-step acceleration/
deceleration changeover speed 7 (sptc7)
and higher as a magnification in respect to
the spindle synchronization
acceleration/deceleration time constant
(spt).
0 to 127
3068 symtm1 Phase synchroniza-
tion start
confirmation time
Set the time to confirm that synchronization
is attained before phase synchronization
control is started.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
0 to 9999 (ms)
3069 symtm2 Phase synchroniza-
tion end
confirmation time
Set the time to wait for phase
synchronization control to end as the time
for the rotation speed to reach the
attainment range.
When "0" is set, the time will be 2 seconds.
When "100" or less is set, the time will be
100ms.
0 to 9999 (ms)
3070 syprt Phase synchroniza-
tion speed
Set the fluctuation amount to change the
synchronous spindle rotation speed during
phase synchronization control as the
command speed and rate.
When "0" is set, the amount will be 100%.
0 to 100 (%)
3071 (Not used.)
3072 (Not used.)