8. SPINDLE PARAMETERS
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
II - 282
No. Items Details
Setting
range
Standard
setting
3457
(PR)
to
3520
(PR)
SP257
to
SP320
RPM
BSD
Motor
constant
(H coil)
This parameter is valid only in the
following two conditional cases:
(a) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=0
Set the motor constants when using a
special motor, not described in the
SP040 (MTYP) explanation and when
not using the coil changeover motor.
(b) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1
Set the motor constant of the H coil of
the coil changeover motor.
(Note) It is not allowed for the user to
change the setting.
0000 to
FFFF
HEX setting
0000
<Details for Motor constant>
No. Items Details
Setting
range
Standard
setting
3494
SP294 Kt Torque
constant for
disturbance
observer
Set the torque constant for disturbance
observer.
30-minute
rated output
× 1000
Setting
(0.01kg•m)=
Base speed × 1.026
× 100
0000 to
FFFF
HEX setting
-
3495
SP295 GDM Motor
inertia for
disturbance
observer
Set the motor inertia for disturbance
observer.
Setting (0.001kg•m
2
)=GD
M
2
× 1000
0000 to
FFFF
HEX setting
-