A SERVICE OF

logo

6. AXIS SPECIFICATIONS PARAMETERS
6.3 Absolute Position Parameters
II - 93
# Items Details Setting range (unit)
2057 nrefp Near zero
point +
Set the width where the near-reference-point signal is
output. (Positive direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
Note: When #1240 set12 (bit2) is ON, a magnification
(C: 10-fold) corresponding to the input setting
unit (#1003 iunit) will be applied on the setting
value.
0 to 32.767 (mm)
2058 nrefn Near zero
point
Set the width where the near-reference-point signal is
output. (Negative direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
Note: When #1240 set12 (bit2) is ON, a magnification
(C: 10-fold) corresponding to the input setting
unit (#1003 iunit) will be applied on the setting
value.
0 to 32.767 (mm)
2059 zerbas Select zero
point
parameter
and reference
point
Specify the position to be the zero point coordinate
during absolute position initial setting.
0: Position that was stopped during stopper
method
Specify the coordinates of the alignment mark
position when using the reference point
method.
1: Grid point just before stopper
Specify the coordinates of the grid point just
before the alignment mark.
0/1