A SERVICE OF

logo

3. PROGRAM ERROR
I - 61
Error No. Details Remedy
P 35 CMD-VALUE OVER
The setting range for the addresses has
been exceeded.
• Check the program.
P 36 PROGRAM END ERR
"EOR" has been read during tape and
memory operation.
• Enter the M02 and M30 command at the end
of the program.
• Enter the M99 command at the end of the
subprogram.
P 37 PROG. NO. ZERO
A zero has been specified for program
and sequence numbers.
The program numbers are designated across
a range from 1 to 99999999.
• The sequence numbers are designated
across a range from 1 to 99999.
P 39 NO SPEC ERR
• A non-specified G code was specified.
The high-speed program server operation
specifications are not provided.
• Check the specifications.
P 40 PREREAD BL. ERR
When tool radius compensation is
executed‚ there is an error in the pre-read
block and so the interference check is
disabled.
• Reconsider the program.
P 60 OVER CMP. LENG.
The commanded movement distance is
excessive. (Over 2
31
)
• Reconsider the axis address command.
P 62 F-CMD. NOTHING
• No feed rate command has been issued.
• There is no F command in the cylindrical
interpolation or pole coordinate
interpolation immediately after the G95
mode is commanded.
• The default movement modal command at
power ON is G01. This causes the machine
to move without a G01 command if a
movement command is issued in the
program, and an alarm results. Use an F
command to specify the feedrate.
• Specify F with a thread lead command.
P 65 NO G05P3 SPEC
• Check the high-speed mode III
specifications.
P 70 ARC ERROR
• There is an error in the arc start and end
points as well as in the arc center.
• The difference of the involute curve
through the start point and the end point is
large.
• When arc was commanded, one of the
two axes configuring the arc plane was a
scaling valid axis.
• Check the numerical values of the addresses
that specify the start and end points, arc
center as well as the radius in the program.
• Check the "+" and "–" directions of the
address numerical values.