5. BASE SPECIFICATIONS PARAMETERS
II - 40
# Items Details Setting range (unit)
1128 RstVCI Clear
variables by
resetting
Specify how to handle the common variables when
resetting.
0: Common variables do not change after
resetting.
1: Common variables #100 to 199 are cleared by
resetting.
0/1
1129 PwrVCl Clear
variables by
power-ON
Specify how to handle the common variables when the
power is turned ON.
0: The common variables are in the same state as
before turning the power OFF.
1: Common variables #100 to 199 are cleared
when the power is turned ON.
0/1
1130 set_t Display
selected tool
number
Specify the tool command value display on the
POSITION screen.
0: T-modal value of program command is
displayed.
1: Tool number sent from PLC is displayed.
0/1
1131
(PR)
Fldcc Feed
forward filter
Parameter to suppress acceleration changes with a
filter when starting acceleration or deceleration
Specify the parameter in bits.
3 0125
46
7
Feed forward filter
bit1: 7.1 (ms)
bit2: 14.2 (ms)
bit3: 28.4 (ms)
bit4: 56.8 (ms)
bit5: 113.6 (ms)
If bit 1 to bit 5 are all 0
or two or more bits of
bit 1 to bit 5 are 1, 3.5
ms is set up.
1132 CRT LCD
brightness
control
This parameter adjusts the brightness of the LCD
display unit.
–3: Highest luminance (Brightest state)
–3: Lowest luminance (Darkest state)
Adjust this parameter to an appropriate brightness
between –3 and 3.
–3 to 3